Verti Afro is an Authorised Suppliers of OEm generator Manufacturer from RAMP Technomation (Ahok Layland) .Vertiafro ready to use DG sets are offered in full range from 5 KVA-2250 KVA. The aesthetically designed silent DG sets meet with latest CPCB emission norms and are offered from various manufacturing locations. We offers total power solution including transportation of DG set, loading unloading, positioning & installation at site which includes Earthing work, cabling work, exhaust piping, fuel line, room treatment and required approval from various bodies.
VA 10
DG SET MODEL:
Power Rating* (KVA): 10
Electric Power (KWE): 8
Rated Current (Amp): 13.9
DG Size L (mm): 1850
W (mm): 900
H (Including Base) (mm): 1333
DG Weight approx (Kg): 650
Fuel Tank Capacity (L): 80
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL485DG1
Engine Rated (KW/Hp): 17.5 / 23.45
Aspiration: NA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 85×92
Displacement (L): 2.088
Fuel Consumtion @ 75% Load* (L/Hr): 2.4
Lube Oil Sump Capacity Approx (L): 8.5
Coolant Capacity Approx (L): 6
Cable Size (sqmm): 16
Governing Class: A0/A1
Governer Used (Electronic/ Mechanical): “Electronic / Mechanical”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 15
DG SET MODEL:
Power Rating* (KVA): 15
Electric Power (KWE): 12
Rated Current (Amp): 20.9
DG Size L (mm): 1850
W (mm): 900
H (Including Base) (mm): 1333
DG Weight approx (Kg): 650
Fuel Tank Capacity (L): 80
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL485DG1
Engine Rated (KW/Hp): 17.5 / 23.45
Aspiration: NA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 85×92
Displacement (L): 2.088
Fuel Consumtion @ 75% Load* (L/Hr): 3
Lube Oil Sump Capacity Approx (L): 8.5
Coolant Capacity Approx (L): 6
Cable Size (sqmm): 25
Governing Class: A0/A1
Governer Used (Electronic/ Mechanical): “Electronic / Mechanical”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 25
DG SET MODEL:
Power Rating* (KVA): 25
Electric Power (KWE): 20
Rated Current (Amp): 34.8
DG Size L (mm): 2000
W (mm): 950
H (Including Base) (mm): 1448
DG Weight approx (Kg): 750
Fuel Tank Capacity (L): 80
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL485TADG3
Engine Rated (KW/Hp): 25 / 33.5
Aspiration: TA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 85×92
Displacement (L): 2.088
Fuel Consumtion @ 75% Load* (L/Hr): 4.8
Lube Oil Sump Capacity Approx (L): 8.5
Coolant Capacity Approx (L): 9
Cable Size (sqmm): 35
Governing Class: A0/A1
Governer Used (Electronic/ Mechanical): “Electronic / Mechanical”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 30
DG SET MODEL:
Power Rating* (KVA): 30
Electric Power (KWE): 24
Rated Current (Amp): 41.7
DG Size L (mm): 2000
W (mm): 950
H (Including Base) (mm): 1448
DG Weight approx (Kg): 750
Fuel Tank Capacity (L): 80
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL485TADG4
Engine Rated (KW/Hp): 25.16 / 38.88
Aspiration: TA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 85×92
Displacement (L): 2.088
Fuel Consumtion @ 75% Load* (L/Hr): 6
Lube Oil Sump Capacity Approx (L): 8.5
Coolant Capacity Approx (L): 9
Cable Size (sqmm): 50
Governing Class: A0/A1
Governer Used (Electronic/ Mechanical): “Electronic / Mechanical”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 35
DG SET MODEL:
Power Rating* (KVA): 35
Electric Power (KWE): 28
Rated Current (Amp): 48.6
DG Size L (mm): 2000
W (mm): 950
H (Including Base) (mm): 1448
DG Weight approx (Kg): 750
Fuel Tank Capacity (L): 80
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL485TADG4
Engine Rated (KW/Hp): 29.16 / 38.88
Aspiration: TA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 85×92
Displacement (L): 2.088
Fuel Consumtion @ 75% Load* (L/Hr): 7.5
Lube Oil Sump Capacity Approx (L): 8.5
Coolant Capacity Approx (L): 9
Cable Size (sqmm): 50
Governing Class: A0/A1
Governer Used (Electronic/ Mechanical): “Electronic / Mechanical”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 40
DG SET MODEL:
Power Rating* (KVA): 40
Electric Power (KWE): 32
Rated Current (Amp): 55.7
DG Size L (mm): 2500
W (mm): 1100
H (Including Base) (mm): 1415
DG Weight approx (Kg): 1100
Fuel Tank Capacity (L): 125
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL4CTDG1
Engine Rated (KW/Hp): 39.21 / 52.28
Aspiration: TA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 104×113
Displacement (L): 3.84
Fuel Consumtion @ 75% Load* (L/Hr): 7.5
Lube Oil Sump Capacity Approx (L): 8.5
Coolant Capacity Approx (L): 13.5
Cable Size (sqmm): 70
Governing Class: A0
Governer Used (Electronic/ Mechanical): “Electronic”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 45
DG SET MODEL:
Power Rating* (KVA): 45
Electric Power (KWE): 36
Rated Current (Amp): 62.55
DG Size L (mm): 2500
W (mm): 1100
H (Including Base) (mm): 1415
DG Weight approx (Kg): 1100
Fuel Tank Capacity (L): 125
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL4CTDG1
Engine Rated (KW/Hp): 39.21 / 52.28
Aspiration: TA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 104×113
Displacement (L): 3.84
Fuel Consumtion @ 75% Load* (L/Hr): 9.1
Lube Oil Sump Capacity Approx (L): 8.5
Coolant Capacity Approx (L): 13.5
Cable Size (sqmm): 50
Governing Class: A0
Governer Used (Electronic/ Mechanical): “Electronic”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 62.5
DG SET MODEL:
Power Rating* (KVA): 62.5
Electric Power (KWE): 50
Rated Current (Amp): 86.9
DG Size L (mm): 2800
W (mm): 1200
H (Including Base) (mm): 1537
DG Weight approx (Kg): 1300
Fuel Tank Capacity (L): 125
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL4CTIDG2
Engine Rated (KW/Hp): 59.31 / 79.09
Aspiration: TA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 104×113
Displacement (L): 3.84
Fuel Consumtion @ 75% Load* (L/Hr): 11.3
Lube Oil Sump Capacity Approx (L): 8.5
Coolant Capacity Approx (L): 13.5
Cable Size (sqmm): 95
Governing Class: A0
Governer Used (Electronic/ Mechanical): “Electronic”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 82.5
DG SET MODEL:
Power Rating* (KVA): 82.5
Electric Power (KWE): 66
Rated Current (Amp): 114.67
DG Size L (mm): 2800
W (mm): 1200
H (Including Base) (mm): 1537
DG Weight approx (Kg): 1550
Fuel Tank Capacity (L): 125
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL4CTIDG3
Engine Rated (KW/Hp): 78.42 / 104.56
Aspiration: TA
No Of Cylider/Coniguration: 4/In-line
Bore xstroke (mm): 104×113
Displacement (L): 3.84
Fuel Consumtion @ 75% Load* (L/Hr): 13.6
Lube Oil Sump Capacity Approx (L): 11
Coolant Capacity Approx (L): 15.5
Cable Size (sqmm): 120
Governing Class: A0
Governer Used (Electronic/ Mechanical): “Electronic”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 100
DG SET MODEL:
Power Rating* (KVA): 100
Electric Power (KWE): 80
Rated Current (Amp): 139
DG Size L (mm): 3300
W (mm): 1250
H (Including Base) (mm): 1600
DG Weight approx (Kg): 1900
Fuel Tank Capacity (L): 185
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL6DTIDG1
Engine Rated (KW/Hp): 94.5 / 126.01
Aspiration: TA
No Of Cylider/Coniguration: 6/In-line
Bore xstroke (mm): 104×113
Displacement (L): 5.76
Fuel Consumtion @ 75% Load* (L/Hr): 17.5
Lube Oil Sump Capacity Approx (L): 17.5
Coolant Capacity Approx (L): 20
Cable Size (sqmm): 150
Governing Class: A0
Governer Used (Electronic/ Mechanical): “Electronic”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 125
DG SET MODEL:
Power Rating* (KVA): 125
Electric Power (KWE): 100
Rated Current (Amp): 173.8
DG Size L (mm): 3300
W (mm): 1250
H (Including Base) (mm): 1600
DG Weight approx (Kg): 1900
Fuel Tank Capacity (L): 185
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL6DTIDG2
Engine Rated (KW/Hp): 116.63 / 155.5
Aspiration: TA
No Of Cylider/Coniguration: 6/In-line
Bore xstroke (mm): 104×113
Displacement (L): 5.76
Fuel Consumtion @ 75% Load* (L/Hr): 21.6
Lube Oil Sump Capacity Approx (L): 17.5
Coolant Capacity Approx (L): 20
Cable Size (sqmm): 185
Governing Class: A0
Governer Used (Electronic/ Mechanical): “Electronic”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 160
DG SET MODEL:
Power Rating* (KVA): 160
Electric Power (KWE): 128
Rated Current (Amp): 222.4
DG Size L (mm): 3900
W (mm): 1350
H (Including Base) (mm): 1750
DG Weight approx (Kg): 2200
Fuel Tank Capacity (L): 185
System Dc Voltage (V): 12
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL6DTIDG4
Engine Rated (KW/Hp): 147.70 / 197.05
Aspiration: TA
No Of Cylider/Coniguration: 6/In-line
Bore xstroke (mm): 104×113
Displacement (L): 5.76
Fuel Consumtion @ 75% Load* (L/Hr): 27.9
Lube Oil Sump Capacity Approx (L): 17.5
Coolant Capacity Approx (L): 25
Cable Size (sqmm): 2×120
Governing Class: A0
Governer Used (Electronic/ Mechanical): “Electronic”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
VA 250
DG SET MODEL:
Power Rating* (KVA): 250
Electric Power (KWE): 200
Rated Current (Amp): 347.5
DG Size L (mm): 4700
W (mm): 1600
H (Including Base) (mm): 2015
DG Weight approx (Kg): 4500
Fuel Tank Capacity (L): 240
System Dc Voltage (V): 24
Battery: Exide Battery
ENGINE SPECIFICATION:
Engine Model: AL8NTIDG3
Engine Rated (KW/Hp): 235.5 / 314
Aspiration: TA
No Of Cylider/Coniguration: 6/In-line
Bore xstroke (mm): 112×135
Displacement (L): 7.98
Fuel Consumtion @ 75% Load* (L/Hr): 40.3
Lube Oil Sump Capacity Approx (L): 25
Coolant Capacity Approx (L): 41
Cable Size (sqmm): 2×180
Governing Class: A0
Governer Used (Electronic/ Mechanical): “Electronic”
Lube Oil Change Period: 600 Hours or 1 Year whichever occurs earlier/250 Hour or 6 months (250 Kva)
Lube Oil Speciication: Gulf XLL Diesel Engine Oil
Alternator: Brushless, Single Bearing, IP23, Class H Insulated, 50Hz, Voltage Regulation +/_1%
Some of the USP of Diesel generating sets are
- 2 year warranty on entire package
- Compact in size
- Low operating costs
- Rugged and suitable for continuous duty applications
- Easy availability of spares and services
- Nation-wide Service network
- One point contact for Engine, Alternator, Panel & Installation
- Low operating cost
- Competitive fuel consumption
AMF control panel (Optional)
- Consists of a microprocessor based AMF Control Unit, which can operate on Auto as well as Manual mode. It monitors the engine safety parameters and alarm/trip conditional will be displayed on the front panel.
- Special alarm conditions include LLOP, HWT, overload, under/over speed, low fuel level. The controller comes with an inbuilt LVM and the parameters can be programmed to meet specific customer requirements.
- The specific indication includes various conditions of operations such as load on mains, Load on DG, Mains Healthy, DG ON, Auto & Manual mode
- The control panel consists of a multi function meter which displays AC Currents/Voltage, Frequency, Power Factor, and Kilowatt Hour. The generator set can be supplied with a standard control panel to operate in manual mode
GC 1201 Generator Controller
- Reads all genset inputs and controls the genset
- Controls the engine speed (Speed governing)
- Supports Auto-Mains-Failure (AMF) functions for 1-Ph and 3-Ph genset
- Supports Manual-Control-Panel(MCP) functions for 1-Ph and 3 Ph genset
- Measures genset voltages & currents
- Measures mains supply voltages & currents
- Measures electrical parameters like Frequency, Power Factor, Genset Power
- Monitors critical engine safety parameters
- Starts and Stops the genset
- Have counters for genset starts and stops, run hours, kWh, power factor
Vertiafro Gensets
Salient Features
- Compact, Modular construction and sleek design with low noise level 75db (a) Whisper.
- Soundproof, weatherproof and environment friendly silent set.
- Silent set designed with international technology to withstand extreme Indian weather conditions.
- Ready-to-use silent set, eliminates need for foundation or grouting.
- Protection and tripping safety devices provided against temperature rise.
- Single bearing generator with inbuilt Anti vibration mounting ensures minimal vibrations, low noise level.
- Customized Residential, Critical and Hospital grade Silencers.
- Silencers having low exhaust noise & back pressure-increased Engine life.
- Acoustic Enclosure is made of compact sleek design confirming to International Standards.
- Type tested and certified noise level of 75-db (a) 1m
Constructional Feature
- Steel outer construction with heavy-duty fabricated base frame and inbuilt fuel tank.
- World class machinery (BEHRENS CNC Turret Punch) for all operations like Punching, Shearing and Notching etc.
- Provides very high accuracy & precise dimensions to components and excellent finishing.
- All hardware (like nuts, bolts, hinges, washers etc.) of stainless steel.
- Bolted design can easily be assembled / dismantled in small components.
- All joints are sealed with reproof neoprene gaskets, which withstand high temperatures and pressures.
- Unique lifting arrangement for easy and safe loading and unloading.
- All high-temperature exposed surfaces are insulated by glass wool with aluminum Cladding.
- Weatherproof, acid-proof, heat resistant, powder-coated after pretreatment for de-greasing, de-rusting, picking phosphating and passivation for Durability and better Aesthetics.